1 in stock
• Common range for a broad network voltages from 100V to 440V.
• Measurement and display of key parameters like voltage, current, power factor, THDV and THDI.
• Fully programmable switching sequence.
• 1A or 5A current input.
• Easy commissioning.
• Complete auto set-up (starting current-C/k, type of switching sequence, phase shift, special connections).
• Easy to use thanks to a user-friendly interface and ease of access to parameters for manual setting.
• Highly efficient switching strategy combining integral, direct and circular switching thereby allowing:
• to control the cos j in presence of rapidly varying loads,
• to reduce the number of switching,
• to avoid unnecessary intermediary switchings,
• to increase the lifetime of the capacitors and contactors.
• Suitable for hot environments due to maximum ambient temperature rating of 70°C.
• Not affected by harmonics.
• Overvoltage / undervoltage protection and protections against harmonic distortion (THDV).
• Alarm : an alarm contact is opened when any of these conditions are reached:
• the target cos j is not reached within 6 minutes after all outputs have been switched on,
• the internal temperature of the RVC rises above 85°C
• overvoltage / undervoltage limits are reached,
• the power supply is out of range,
• the THDV exceeds the limits.
– Incoterm: Ex-work
– Preliminary Calculation of Product Transportation Costs:
Customers are responsible for arranging transportation through their preferred shipping provider. For convenience, estimated shipping costs can be calculated via DHL using the link provided on our website, as our company is a registered DHL member.
Once payment for both the products and shipping fees has been completed, customers may contact DHL at the origin to coordinate direct pickup from the factory.
ABB OS400D03P
(Surplus stock : New)
Switch Fuses,Front Operated,3-pole,03 (Left Side),DIN,0,1,2,Handle and shaft included,
ABB A300-30-11
Surplus stock : New (in original box)
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
ABB SACE TMAX XT3N-250
(Surplus stock : New in original box)
C.BREAKER TMAX XT3N 250 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 250-2500 A
Schneider Magnetic Contactor LC1-D150M7
( Surplus stock : New with Box )
Telemecanique (TeSys Control Deca) – 3-poles (3P; 3NO) – 150A (AC-3) rated current – 176-253Vac (220Vac nom.; 50Hz/60Hz) coil – Screw connections – 1NO+1NC aux. contacts – 75kW (380-400Vac; AC-3) / 100HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA) rated power – DIN rail – IP20 – Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.)
Transformer: TTM 250 KVA — SOLD OUT!
ABB Circuit Breaker T6N 800 3p
(Surplus stock : New in original box)
C.BREAKER TMAX T6N 800 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR221DS-LS/I R 800