GMI D1072D

GMI D1072D Din-Rail

(Surplus stock : Stock )

SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models  D1072D

The single and dual channel DIN Rail Temperature Signal Converter D1072S and D1072D accepts a low level dc signal from millivolt, thermocouple or RTD temperature sensor, located in Hazardous Area, and converts, with isolation, the signal to drive a Safe Area load. Output signal can be direct or reverse. Duplicator function provides two independent outputs for the single input. Adder, subtractor, low/high selector functions provides two independent outputs representing input A, input B, input A plus input B, input A minus input B, low/high selector.

 

$300.00

 / EA

In Stock : 1

Available for Order

PRODUCT OVERVIEW

GMI D1072D Din-Rail

SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models  D1072D

The single and dual channel DIN Rail Temperature Signal Converter D1072S and D1072D accepts a low level dc signal from millivolt, thermocouple or RTD temperature sensor, located in Hazardous Area, and converts, with isolation, the signal to drive a Safe Area load. Output signal can be direct or reverse. Duplicator function provides two independent outputs for the single input. Adder, subtractor, low/high selector functions provides two independent outputs representing input A, input B, input A plus input B, input A minus input B, low/high selector.

Technical Data

  • SIL2/SC2
  • Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2.
  • mV, thermocouples, RTD or transmitting potentiometers Input Signal.
  • Programmable RTD line resistance compensation.
  • Reference Junction Compensation automatic or fixed (programmable value).
  • 0/4-20 mA, 0/1-5 V, 0/2-10 V. Output Signal temperature linear or reverse.
  • Duplicated output for single channel input.
  • Adder, Subtractor, low/high Selector.
  • 16 characters tag for each channel.
  • Common burnout detection available when using Power Bus enclosure.
  • High Accuracy, µP controlled A/D converter.
  • Three port isolation, Input/Output/Supply.
  • EMC Compatibility to EN61000-6-2, EN61000-6-4.
  • Fully programmable operating parameters.
  • High Density, two channels per unit.
  • 250 Vrms (Um) max. voltage allowed to the Instruments associated with the barrier.

PRODUCT RELATED

SIEMENS SIMATIC S7-200 CN 6ES7-0AA22-0XA0

Surplus stock : New open box

$260.00

 / EA

In Stock : 1

Available for Order

GEMS™ Transducer Sensor & Controls: 26ICBGB2502GBUB

Surplus stock : New

 

$280.00

 / EA

In Stock : 2

Available for Order

ABB Overload TA25GU-2.4

(Surplus Stock : New )

The TA25DU-2.4 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.

$30.00

In Stock : 5

Available for Order

SIL 3 Relay Output Module D1092S
(Surplus stock : New )

The single channel DIN Rail Relay Output, D1092S, is relay module suitable for the switching of safety related circuits, up to SIL 3 level according to IEC61508:2010 Ed. 2, for high-risk industries. It provides isolation between input and output contacts. D1092S provides 1 SPST contact for normally energized loads and 1 SPST contact for normally de-energized loads. When the relay is energized, the contacts are closed. When the relay is de-energized, the contacts are open. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signaling, driving LEDs, etc.).

$130.00

 / EA

In Stock : 2

Available for Order

GMI D5014S L.S.SIL3 2/4-Wire HART Transmitter Power Supply
(Surplus Stock : New)

The Repeater Power Supply D5014 module is a high integrity analog input interface suitable for applications requiring SIL 3 level in safety related systems for high-risk industries. It provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA, active or passive, transmitters located in Hazardous Area and repeats the current in floating circuit to drive a Safe Area load. The module supports output current duplication, and it allows bi-directional communication signals, for HART® devices.

$400.00

 / EA

In Stock : 1

Available for Order

Surplus stock : New

ABB OS250D03P

(Surplus stock : New )

Switch Fuses, Front Operated, 3-pole, 03 (Left Side), DIN, 0, 1, Handle and shaft included,

$720.00

 / EA

In Stock : 12

Available for Order

Surplus stock : New
YOGOKAWA Temperature Transmitter 
Model: YTA110-EA2DB2KU2
YOGOKAWA Temperature Transmitter 0 to 600°c
Surplus Stock (New)

$600.00

 / EA

In Stock : 20

Available for Order

Surplus stock : New

SIMATIC PCS7 SINGLE CPU410E 200PO : 1 System.

$28,500.00

 / Lot

In Stock : 1

Available for Order

Surplus stock : New

SIMATIC S7-400, Backup battery 3.6 V/2.3 AH for PS 405 4 A/10 A/20 A and PS 407 4 A/10 A/20 A

Ord. 6ES7971-0BA00

$16.00

 / EA

In Stock : 4

Available for Order

PROFIBUS FC Standard Cable GP, bus cable 2-wire, shielded, special configuration for quick assembly, Delivery unit: max. 1000 m, minimum order quantity 20 m sold by the meter

$70.00

 / EA

In Stock : 1

Available for Order