ABB AF400-30-11
(Surplus stock : New)
The AF400-30-11 is a 3 pole – 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 350 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 550 A UL general use. Thanks to the AF technology, the c
ABB AF400-30-11
(Surplus stock : New )
The AF400-30-11 is a 3 pole – 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) or 350 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 550 A UL general use. Thanks to the AF technology, the c
WEG Explosion Proof Motors — 185 KW
Surplus stock : New
Motor 185 KW Weg 310UT08 1003335794 / ▲t 75K /3∅ Ph / A =353 / 0.85 COS¢ / V=380 / Hz=50 / min(-1)=1490 / DUTY=S1/INS CL=F /ALT=1000 m.a.s / IP 55 /T.Amb 40°C / S.F1.15 /PF=0.83 /II 2G EEx de11B 14/SCREW OF FASTENING CLASS 12.9 /WEIGHT=1623 Kg.
Schneider LC1-D18-M7 Contactor
Description: TeSys D contactor – 3P(3 NO) – AC- 3 – <= 440 V 18 A – 220 V AC coil
Schneider LC1-D115-M7 Contactor
LC1D115 Schneider Electric 115 AMP, 3 pole contactor with an AC rated coil (must specify voltage below). Rated 75 H.P. 460 volts 3-Phase and has 1 N.O. and 1 N.C. base mounted auxiliary contact
ABB A300-30-11
(Surplus stock : New)
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
ABB AF580-30-11
(Surplus stock : New)
The AF580-30-11-70 is a 3 pole – 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 315 kW / 400 V AC (AC-3) or 500 hp / 480 V UL and switching power circuits up to 800 A (AC-1) or 750 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Power Factor Controller – EPCOS BR6000-R12
(Surplus Stock : New)
Schneider Magnetic Contactor LC1-D150M7
( Surplus stock : New with Box )
Telemecanique (TeSys Control Deca) – 3-poles (3P; 3NO) – 150A (AC-3) rated current – 176-253Vac (220Vac nom.; 50Hz/60Hz) coil – Screw connections – 1NO+1NC aux. contacts – 75kW (380-400Vac; AC-3) / 100HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA) rated power – DIN rail – IP20 – Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.)
ABB MS132-25 Manual Motor Starter 20 … 25 A
(Surplus stock : New )
The MS132-25 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 25.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
ABB UA30-30-10 Contactor
(Surplus stock : New )
The UA30-30-10 220-230V 50Hz / 230-240V 60Hz is a 3-pole contactor for capacitor switching, can be used for the switching of capacitor banks whose inrush current peaks are less than or equal to 100 times nominal rms current. The table below gives the permissible powers according to operational voltage and temperature close to the contactor. It also specifies the maximum peak current Î values accepted by the contactor. The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. In these conditions, electrical durability of contactors is equal to 100 000 operating cycles. The UA.. series 3-pole contactors are of the block type design. – Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact – Control circuit: AC operated with laminated magnet circuit – Accessories: a wide range of accessories is available.
ABB Circuit Breaker T7S 1250 PR231/P LS/I In=1250A 3p F F
(Surplus stock : New )
C.BREAKER TMAX T7S 1250 FIXED THREE-POLE WITH FRONT TERMINALS AND LEVER OPERATING MECHANISM AND SOLID-STATE RELEASE IN AC PR231/P-LS/I R 1250
91/149 Moo 5, Bannmai, Pakkret,
Nonthaburi 11120 THAILAND
16/224, 16/242 Moo 3, Bannmai, Mueang Pathum Thani, Pathum Thani 12000 THAILAND
16/224, 16/242 Moo 3, Bannmai,
Mueang Pathum Thani, Pathum Thani
12000 THAILAND